The MIT2500 insulation and continuity tester has been designed for motor and cable testing, specialist applications and electrical testing applications, where operation voltages exceed 1000 V and higher insulation test voltages are needed.
The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be “dialed in”. This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.
Overview
Features
- Insulation testing up to 2.5 kV and 200 GΩ range in a hand held instrument
- Guard terminal for high resistance accuracy
- Adjustable insulation test voltage from 50 V to 2500 V
- Stabilized insulation test voltage
- Rechargeable options for mains and car charging
- Single range, faster continuity testing from 0.01 Ω to 1 MΩ
- Polarization Index (PI) & Dielectric Absorption Ratio (DAR)
- CAT IV 600 V applications
- Polarization Index (PI) & Dielectric Absorption Ratio (DAR)
- CAT IV 600 V applications
Functions
- Continuity buzzer limit alarms
- Insulation buzzer limit alarms
- Insulation LOCK
- Insulation test timer duration
- Backlight ON duration
- Sleep timer
- Continuity test currents
- Factory reset
Applications
- Commercial Avionics
- Military Land, Marine and Air communications
- Manufacturing/production line goods
- Electrostatic measurement
- Component testing
- Battery powered traction and lifting equipment
Specifications
Guard terminal performance | <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load |
Display Range | Analog: 1 GΩ full scale |
Resolution | 0.1 kΩ |
Short circuit/charge current | 2 mA +0% -50% to EN61557-2 (2007) [except 2500 V] |
Terminal voltage accuracy | -0% +2% ± 2 V |
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max |
Operation | EN61557 : 0.10 MΩ to 1.0 GΩ |
Leakage current | 10% ±3 digits |
Display voltage | ±3 ±2 digits ±0.5% of rated voltage |
Timer control | Countdown timer 60 second (adjustable to 10 minutes) |
Dimensions | 9.00 in x 4.25 in x 2.32 in (2.28 mm x 108 mm x 63 mm) |
Weight | 1.8 lb (815 g) |
What’s in the Box
- Megger MIT2500 Hand-Held Insulation and Continuity Tester
- Red/Black/Blue 1 kV Silicone Test Leads with Probes and Clips (1007-781)
- Red/Black/Blue 2.5 kV Silicone Test Leads with Clips (1007-637)
- Owners Information CD
- Batteries 6 x AA Alkaline (1002-753)
- Hard Carry Case (2006-649)
Resources
Megger MIT2500 Spec Sheet