The Digital Ground Resistance Tester Model 6472 is a portable measurement instrument designed to measure Bond Resistance, Ground Resistance (with and without clamps), Soil Resistivity, Earth Coupling, Step & Touch Potential.
When used in combination with the GroundFlex® Adapter Model 6474 (factory supplied product only), Power Transmission Tower and Tower Leg Ground Resistance testing is also available.
Overview
- 4-Pole (4-Point) Fall-of-Potential measurement for very low resistance measurements with manual or automatic frequency selection and automatic lead compensation
- 3-Point Fall-of-Potential measurement
- 3-Point earth coupling measurement
- Manual or automatic frequency scan from 40 to 513 Hz for test accuracy in electrically noisy environments
- Earth coupling testing
- Selectable test voltage 16 or 32 V up to 250 mA test current
- 4-Point soil resistivity measurement with automatic calculation of Rho and user selection of Wenner or Schlumberger test method
- 2- and 4-Wire DC resistance measurement (Bond testing) with automatic polarity reversal
- Ground Resistance with 2 clamps (no auxiliary rods)
- Ground Resistance of Pylons with the GroundFlex® Adapter Model 6474 and GroundFlex® sensors allow the system to measure leakage current and ground resistance of tower legs without disconnecting the overhead ground conductor
- Includes DataView® software for data storage, real-time display, analysis, report generation and system configuration
- Auto-off power management
- Automatic recognition of all electrode connections and their resistance value
- Stores up to 512 complete test results in internal memory
- Optically isolated USB communication
- Rechargeable NiMH batteries from wall charger or vehicle power
- Rugged dustproof and rainproof field
Specifications
4-Point Earth Resistance Measurement | |
Range (Auto-Ranging) | 0.011Ω to 99.99kΩ |
Resolution | 0.001 to 10Ω |
Accuracy | ±(2% Reading +1ct) |
Test Voltage | 16 or 32V; 41 to 5078Hz |
Test Current | Up to 250mA |
Selective 4-Pole (with optional probes MN82 or SR182) | |
Same characteristics as with 4-point earth resistance measurement | |
3-Point Earth Resistance Measurement | |
Range (Auto-Ranging) | 0.09Ω to 99.9kΩ |
Resolution | 0.01 to 100Ω |
Accuracy | ±(2% Reading +1ct) |
Test Voltage | 16 or 32V; 41 to 5078Hz |
Test Current | Up to 250mA |
Soil Resistivity 4-Point Measurement | |
Test method | Wenner or Schlumberger selectable with automatic calculation |
Range (Auto-Ranging) | 0.01 to 99.9kΩ; ρ max: 999kΩm |
Resolution | 0.01 to 100Ω |
Accuracy (Typical) | ±(2% Reading +1ct) |
Test Voltage | 16 or 32V; 41 to 128Hz selectable |
Earth/Ground Potential Measurement V Pot | |
Range (Auto-Ranging) | 0.01mV to 65.00V |
Resolution | 0.01 to 10mV |
Accuracy (Typical) | ±(5% Reading +1ct) |
Test Voltage | 16 or 32V; 41 to 5078Hz |
2 Clamp Ground Measurement (with optional probes MN82 or SR182) | |
Range (Auto-Ranging) | 0.1 to 500Ω |
Resolution | 0.01 to 1Ω |
Measurement Frequency | Auto: 1611Hz; Manual: 128Hz-1367Hz-1611Hz-1758Hz |
DC Resistance Measurement (Bond Testing) 2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) |
|
Range (Auto-Ranging) | 2-pole: 0.12Ω to 99.9kΩ 4-pole: 0.020Ω to 99.99kΩ |
Resolution | 2 -pole: 0.01 to 100Ω 4-pole: 0.001 to 10Ω |
Accuracy (Typical) | ±(2% Reading +2ct) |
Test Voltage | 16V DC; (+, – or auto polarity) |
Test Current | Up to 250mA |
Current Measurement (with optional probes MN82 or SR182) | |
Range | 0.01mA to 40A, 16 to 400Hz |
Accuracy (Typical) | ±(3% Reading +2ct) typical |
External Voltage Measurement | |
Range | 0.1 to 65V AC/DC – DC, 15 to 440Hz |
Accuracy | ±(2% Reading +1ct) |
General Features | |
Pylon Ground Testing | Available by connecting AEMC Model 6474 and a set of GroundFlex sensors |
Memory | 512 measurements (64KB) |
Communication | USB 2.0 optically isolated, DataView software included |
Power Source | 9.6V rechargeable battery pack with external 110/220V charger |
Battery Life | 1500 tests typical in automatic mode |
Dimensions | 10.7 x 9.80 x 5.12” (272 x 248 x 130mm) |
Weight | 7lbs. (3.2kg) with battery |
Case | UL V0 Polypropylene |
Operating Temperature | 32° to +113°F (0° to +45°C) |
Storage Temperature | -40° to 158°F (-40° to +70°C) |
Relative Humidity | Up to 90% |
Ingress Protection (IP) | IP 53 with cover closed |
EMC | EN 61326-1 |
Safety Compliance | IEC 61010-1, EN 61557, 50V CAT IV, Pollution Degree 2 |
What’s in the Box
- Digital Multifunctional Ground Resistance Tester
- Optical USB Cable
- Power Adapter 110/240V with Power Cord 115 V US
- 2 x 300′ Color-Coded Leads on Spools (Red/Blue)
- 2 x 5′ Color-Coded Leads (Red/Blue)
- 2 x 100′ Color-Coded Leads (Green and Black)
- 4 x 14.5″ T-Shaped Auxiliary Ground Electrodes
- 5 x Spaded Lugs
- 100′ Tape Measure
- USB stick with DataView software and ground tester workbook
- User Manual
- Carrying Bag
- Rechargeable NiMH Battery Pack
Resources
AEMC 6472 Kit Spec Sheet